Long Term Development Statement (LTDS) Table 2b Transformer Data - 3W
Dataset schema
Click to expand Click to collapse
JSON Schema
The following JSON object is a standardized description of your dataset's schema. More about JSON schema.
{
- "title":"ltds-table-2b-transformer-data-3w",
- "type":"object",
- "oneOf":,[
- {
- "$ref":"#/definitions/ltds-table-2b-transformer-data-3w"
}
] - "definitions":{
- "ltds-table-2b-transformer-data-3w":,{
- "properties":{
- "records":{
- "type":"array",
- "items":{
- "$ref":"#/definitions/ltds-table-2b-transformer-data-3w_records"
}
}
} - "records":
} - "properties":
- "ltds-table-2b-transformer-data-3w_records":{
- "properties":{
- "fields":{
- "type":"object",
- "properties":{
- "id":,{
- "type":"integer",
- "title":"ID",
- "description":""
} - "licencearea":,{
- "type":"string",
- "title":"LicenceArea",
- "description":"This holds the Licence Area or DNO (Distribution Network Operator) name"
} - "gridsupplypoint":,{
- "type":"string",
- "title":"GridSupplyPoint",
- "description":"This is the point of delivery from the transmission system to a distribution system"
} - "hv_node":,{
- "type":"string",
- "title":"HV_Node",
- "description":""
} - "hv_substation":,{
- "type":"string",
- "title":"HV_Substation",
- "description":"The Name of the Site as per the UK Power Networks Control and Asset Management System"
} - "voltage_hv":,{
- "type":"string",
- "title":"Voltage_HV (kV)",
- "description":"Highest voltage on the site",
- "unit":"kV"
} - "lv_node_1":,{
- "type":"string",
- "title":"LV_Node_1",
- "description":""
} - "lv_substation_1":,{
- "type":"string",
- "title":"LV_Substation_1",
- "description":"The Name of the Site as per the UK Power Networks Control and Asset Management System"
} - "voltage_lv_1":,{
- "type":"string",
- "title":"Voltage_LV_1 (kV)",
- "description":"Highest voltage on the LV1 site",
- "unit":"kV"
} - "sitefunctionallocation":,{
- "type":"string",
- "title":"SiteFunctionalLocation",
- "description":""
} - "lv_node_2":,{
- "type":"string",
- "title":"LV_Node_2",
- "description":""
} - "lv_substation_2":,{
- "type":"string",
- "title":"LV_Substation_2",
- "description":"The Name of the Site as per the UK Power Networks Control and Asset Management System"
} - "voltage_lv_2":,{
- "type":"string",
- "title":"Voltage_LV_2 (kV)",
- "description":"Highest voltage on the LV2 site",
- "unit":"kV"
} - "vector_group_hv":,{
- "type":"string",
- "title":"Vector_Group_HV",
- "description":"Vector Group HV Side"
} - "vector_group_lv1":,{
- "type":"string",
- "title":"Vector_Group_LV1",
- "description":"Vector Group LV Side Winding 1"
} - "vector_group_lv2":,{
- "type":"string",
- "title":"Vector_Group_LV2",
- "description":"Vector Group LV Side Winding 2"
} - "positive_sequence_impedance_r_hv_lv1_percent":,{
- "type":"number",
- "title":"Positive_Sequence_Impedance_R_HV_LV1_Percent",
- "description":"Tx Positive Sequence Resistance HV to LV Winding 1",
- "unit":"%"
} - "positive_sequence_impedance_r_hv_lv2_percent":,{
- "type":"number",
- "title":"Positive_Sequence_Impedance_R_HV_LV2_Percent",
- "description":"Tx Positive Sequence Resistance HV to LV Winding 2",
- "unit":"%"
} - "positive_sequence_impedance_r_lv1_lv2_percent":,{
- "type":"number",
- "title":"Positive_Sequence_Impedance_R_LV1_LV2_Percent",
- "description":"Tx Positive Sequence Resistance LV Winding 1 to LV Winding 2",
- "unit":"%"
} - "positive_sequence_impedance_x_hv_lv1_percent":,{
- "type":"number",
- "title":"Positive_Sequence_Impedance_X_HV_LV1_Percent",
- "description":""
} - "positive_sequence_impedance_x_lv1_lv2_percent":,{
- "type":"number",
- "title":"Positive_Sequence_Impedance_X_LV1_LV2_Percent",
- "description":""
} - "positive_sequence_impedance_x_hv_lv2_percent":,{
- "type":"number",
- "title":"Positive_Sequence_Impedance_X_HV_LV2_Percent",
- "description":""
} - "zero_sequence_impedance_x_hv_lv1_percent":,{
- "type":"number",
- "title":"Zero_Sequence_Impedance_X_HV_LV1_Percent",
- "description":"Tx Zero Sequence Reactance HV Winding to LV Winding 1",
- "unit":"%"
} - "zero_sequence_impedance_x_hv_lv2_percent":,{
- "type":"number",
- "title":"Zero_Sequence_Impedance_X_HV_LV2_Percent",
- "description":"Tx Zero Sequence Reactance HV Winding to LV Winding 2",
- "unit":"%"
} - "zero_sequence_impedance_x_lv1_lv2_percent":,{
- "type":"number",
- "title":"Zero_Sequence_Impedance_X_LV1_LV2_Percent",
- "description":"Tx Zero Sequence Reactance LV Winding 1 to LV Winding 2",
- "unit":"%"
} - "tap_range_min_percent_hv":,{
- "type":"integer",
- "title":"Tap_Range_Min_Percent_HV",
- "description":"Minimum HV Tx Tap Range",
- "unit":"%"
} - "tap_range_min_percent_lv1":,{
- "type":"integer",
- "title":"Tap_Range_Min_Percent_LV1",
- "description":"Minimum LV1 Tx Tap Range",
- "unit":"%"
} - "tap_range_min_percent_lv2":,{
- "type":"integer",
- "title":"Tap_Range_Min_Percent_LV2",
- "description":"Minimum LV2 Tx Tap Range",
- "unit":"%"
} - "tap_range_max_percent_hv":,{
- "type":"integer",
- "title":"Tap_Range_Max_Percent_HV",
- "description":"Maximum HV Tx Tap Range",
- "unit":"%"
} - "tap_range_max_percent_lv1":,{
- "type":"integer",
- "title":"Tap_Range_Max_Percent_LV1",
- "description":"Maximum LV1 Tx Tap Range",
- "unit":"%"
} - "tap_range_max_percent_lv2":,{
- "type":"integer",
- "title":"Tap_Range_Max_Percent_LV2",
- "description":"Maximum LV2 Tx Tap Range",
- "unit":"%"
} - "transformer_rating_mva_summer_hv":,{
- "type":"integer",
- "title":"Transformer_Rating_MVA_Summer_HV",
- "description":"Tx HV Rating Summer"
} - "transformer_rating_mva_winter_hv":,{
- "type":"integer",
- "title":"Transformer_Rating_MVA_Winter_HV",
- "description":"Tx HV Rating Winter"
} - "transformer_rating_mva_summer_lv1":,{
- "type":"integer",
- "title":"Transformer_Rating_MVA_Summer_LV1",
- "description":"Tx LV1 Rating Summer"
} - "transformer_rating_mva_winter_lv1":,{
- "type":"integer",
- "title":"Transformer_Rating_MVA_Winter_LV1",
- "description":"Tx LV1 Rating Winter"
} - "transformer_rating_mva_summer_lv2":,{
- "type":"integer",
- "title":"Transformer_Rating_MVA_Summer_LV2",
- "description":"Tx LV2 Rating Summer"
} - "transformer_rating_mva_winter_lv2":,{
- "type":"integer",
- "title":"Transformer_Rating_MVA_Winter_LV2",
- "description":"Tx LV2 Rating Winter"
} - "reverse_power_capability_percent":,{
- "type":"string",
- "title":"Reverse_Power_Capability_Percent",
- "description":"Reverse Power Capability"
} - "method_of_earthing_hv":,{
- "type":"string",
- "title":"Method_of_Earthing_HV",
- "description":"Tx HV Side Earth Method"
} - "method_of_earthing_lv1":,{
- "type":"string",
- "title":"Method_of_Earthing_LV1",
- "description":""
} - "method_of_earthing_lv2":{
- "type":"string",
- "title":"Method_of_Earthing_LV2",
- "description":"Tx LV2 Side Earth Method"
}
} - "id":
}
} - "fields":
} - "properties":
} - "ltds-table-2b-transformer-data-3w":
}